Which part of the microscope is to be adjusted so that the greatest amount of light will pass through in the stage?

A high power or compound microscope achieves higher levels of magnification than a stereo or low power microscope. It is used to view smaller specimens such as cell structures which cannot be seen at lower levels of magnification. Essentially, a compound microscope consists of structural and optical components. However, within these two basic systems, there are some essential components that every microscopist should know and understand. These key microscope parts are illustrated and explained below.

STRUCTURAL COMPONENTS

The three basic, structural components of a compound microscope are the head, base and arm.

  • Head/Body houses the optical parts in the upper part of the microscope
  • Base of the microscope supports the microscope and houses the illuminator
  • Arm connects to the base and supports the microscope head. It is also used to carry the microscope.

When carrying a compound microscope always take care to lift it by both the arm and base, simultaneously.

Which part of the microscope is to be adjusted so that the greatest amount of light will pass through in the stage?

OPTICAL COMPONENTS

There are two optical systems in a compound microscope: Eyepiece Lenses and Objective Lenses:

Eyepiece or Ocular is what you look through at the top of the microscope. Typically, standard eyepieces have a magnifying power of 10x. Optional eyepieces of varying powers are available, typically from 5x-30x. 

Eyepiece Tube holds the eyepieces in place above the objective lens. Binocular microscope heads typically incorporate a diopter adjustment ring that allows for the possible inconsistencies of our eyesight in one or both eyes. The monocular (single eye usage) microscope does not need a diopter. Binocular microscopes also swivel (Interpupillary Adjustment) to allow for different distances between the eyes of different individuals.

Objective Lenses are the primary optical lenses on a microscope. They range from 4x-100x and typically, include, three, four or five on lens on most microscopes. Objectives can be forward or rear-facing.

Nosepiece houses the objectives. The objectives are exposed and are mounted on a rotating turret so that different objectives can be conveniently selected. Standard objectives include 4x, 10x, 40x and 100x although different power objectives are available.

Coarse and Fine Focus knobs are used to focus the microscope. Increasingly, they are coaxial knobs - that is to say they are built on the same axis with the fine focus knob on the outside. Coaxial focus knobs are more convenient since the viewer does not have to grope for a different knob.

Stage is where the specimen to be viewed is placed. A mechanical stage is used when working at higher magnifications where delicate movements of the specimen slide are required.

Stage Clips are used when there is no mechanical stage. The viewer is required to move the slide manually to view different sections of the specimen.

Aperture is the hole in the stage through which the base (transmitted) light reaches the stage.

Illuminator is the light source for a microscope, typically located in the base of the microscope. Most light microscopes use low voltage, halogen bulbs with continuous variable lighting control located within the base.

Condenser is used to collect and focus the light from the illuminator on to the specimen. It is located under the stage often in conjunction with an iris diaphragm.

Iris Diaphragm controls the amount of light reaching the specimen. It is located above the condenser and below the stage. Most high quality microscopes include an Abbe condenser with an iris diaphragm. Combined, they control both the focus and quantity of light applied to the specimen.

Condenser Focus Knob moves the condenser up or down to control the lighting focus on the specimen.

Which part of the microscope is to be adjusted so that the greatest amount of light will pass through in the stage?

A microscope is a high quality instrument and should last 25-30 years if treated properly and with care. Following these simple instructions will not only help you care for your microscope and keep it in good working condition, but will also help you get the most out of your microscope.

Which part of the microscope is to be adjusted so that the greatest amount of light will pass through in the stage?

  1. When moving your microscope, always carry it with both hands (Figure 1, at left). Grasp the arm with one hand and place the other hand under the base for support.
  2. Turn the revolving nosepiece so that the lowest power objective lens is "clicked" into position (This is also the shortest objective lens).
  3. Your microscope slide should be prepared by placing a coverslip or cover glass over the specimen. This will help protect the objective lenses if they touch the slide.  Place the microscope slide on the stage and fasten it with the stage clips.  You can push down on the back end of the stage clip to open it.
  4. Which part of the microscope is to be adjusted so that the greatest amount of light will pass through in the stage?
    Look at the objective lens and the stage from the side (Figure 2, at right) and turn the coarse focus knob so that the objective lens moves downward (or the stage, if it moves, goes upward). Move it as far as it will go without touching the slide!
  5. Now, look through the eyepiece and adjust the illuminator (or mirror) and diaphragm (Figure 3,
    Which part of the microscope is to be adjusted so that the greatest amount of light will pass through in the stage?
    at left) for the greatest amount of light.
  6. Slowly turn the coarse adjustment so that the objective lens goes up (away from the slide). Continue until the image comes into focus. Use the fine adjustment, if available, for fine focusing.  If you have a microscope with a moving stage, then turn the coarse knob so the stage moves downward or away from the objective lens.
  7. Move the microscope slide around so that the image is in the center of the field of view and readjust the mirror, illuminator or diaphragm for the clearest image.
  8. Now, you should be able to change to the next objective lens with only minimal use of the focusing adjustment. Use the fine adjustment, if available. If you cannot focus on your specimen, repeat steps 4 through 7 with the higher power objective lens in place. Do not allow the objective lens to touch the slide!
  9. The proper way to use a monocular microscope is to look through the eyepiece with one eye and keep the other eye open (this helps avoid eye strain). If you have to close one eye when looking into the microscope, it's ok.  Remember, everything is upside down and backwards. When you move the slide to the right, the image goes to the left!
  10. Do not touch the glass part of the lenses with your fingers. Use only special lens paper to clean the lenses.
  11. When finished, raise the tube (or lower the stage), click the low power lens into position and remove the slide.
  12. Always keep your microscope covered when not in use. Dust is the number one enemy!

Remember, microscopes are expensive scientific instruments. Handle them properly and carefully and they will last for many years!

What part of the microscope adjusts the amount of light?

IRIS DIAPHRAGM CONTROL — A lever (or rotating disk) that adjusts the amount of light illuminating the slide. Use just enough light to illuminate the object on the slide and give good contrast.

What part of the microscope should be adjusted in order to have the greatest amount of light?

Adjust the condenser (7) and light intensity for the greatest amount of light.

What part of the microscope is used to adjust the amount of light passing through the condenser?

The iris diaphram is an adjustable shutter which allows you to adjust the amount of light passing through the condenser. The angle determines the Numerical Aperture (NA) of the condenser. This diaphragm, generally called the aperture diaphragm, is one of the most important controls on the microscope.

What is the best way to adjust the amount of light entering the microscope?

The amount of light entering a microscope may be adjusted by regulating the diaphragm, therefore the answer is b. The diaphragm, also called the iris diaphragm, adjusts the size and intensity of the cone of light that reaches the specimen.