What principles must be observed to avoid damage to the centrifuge or the specimen and danger to personnel?

  • Journal List
  • J Oral Maxillofac Pathol
  • v.17(3); Sep-Dec 2013
  • PMC3927343

J Oral Maxillofac Pathol. 2013 Sep-Dec; 17(3): 402–407.

Abstract

Histopathology is an art of analyzing and interpreting the shapes, sizes and architectural patterns of cells and tissues within a given specific clinical background and a science by which the image is placed in the context of knowledge of pathobiology, to arrive at an accurate diagnosis. To function effectively and safely, all the procedures and activities of histopathology laboratory should be evaluated and monitored accurately. In histopathology laboratory, the concept of quality control is applicable to pre-analytical, analytical and post-analytical activities. Ensuring safety of working personnel as well as environment is also highly important. Safety issues that may come up in a histopathology lab are primarily those related to potentially hazardous chemicals, biohazardous materials, accidents linked to the equipment and instrumentation employed and general risks from electrical and fire hazards. This article discusses quality management system which can ensure quality performance in histopathology laboratory. The hazards in pathology laboratories and practical safety measures aimed at controlling the dangers are also discussed with the objective of promoting safety consciousness and the practice of laboratory safety.

Keywords: Histopathology, quality, safety

INTRODUCTION

Quality is the degree to which healthcare services strive to provide accurate desired outcomes for patients and are consistent with current professional knowledge. As pathology is pivotal to health care, deterioration in the quality of pathology services can compromise patient care and lead to adverse health events.[1] Quality analysis are well-established in the departments such as clinical biochemistry and hematology where numerical data is obtained compared to histopathology laboratory where reports contain interpretations, explanations, evaluations of probability and clinical judgments. Assessment and implementation of quality control in histopathology is not easy as its output is wholly qualitative rather than quantitative.[2] An integrated coordination between technical and managerial activities along with highly skilled pathologist is essential for the continuous, unimpeded realization of high quality, error-free, efficient and effective laboratory operations.[3]

Equally important is safety, which is defined as “freedom from accidental injury”. Healthcare system should be safer at all levels to prevent errors.[1] The hazards that workers in pathology laboratories face include specific risks from toxic chemicals which are used in investigative procedures, pathogenic microorganisms in patient's samples and general risks from mechanical, electrical and fire hazards. The danger can be aggravated by ignorance of the hazards, lack of knowledge on safety measures and inadequate safety measures adopted by laboratories.[4] Safety consciousness and safe laboratory practices are therefore of primary importance for the protection of laboratory workers against injury and infection and the prevention of damage to property.

To ensure quality and safety in histopathology laboratory, it is imperative that there be a clear understanding of quality and safety control program and implementation of the same. Therefore, in this article we are making an attempt to describe the steps involved in producing a quality histopathology report and safety measures for minimizing the risk in histopathology laboratory.

LABORATORY QUALITY MANAGEMENT SYSTEM

To ensure the quality performance, every laboratory should have some form of quality management system for all the procedures performed under its scope of activity. Quality assurance, continuing quality improvement and quality control are integral component of a required ‘quality system’.[5]

Quality control

Quality control is a system of routine technical activities, to measure and control the quality of the inventory as it is being developed. It provides routine and consistent checks to identify, address errors and omissions, ensures data integrity, correctness and completeness and also records all quality control activities.[6] The quality control checks in a histopathology lab will include accurate patient identification, fixation, adequate processing, appropriate embedding techniques, microtomy, unacceptable artifacts and inspection of controls to determine correctness of special stains and immunohistochemical methods.[5] It is the responsibility of the pathologist to perform the final quality control examination as they read the slide and determine whether the slide is adequate for the diagnostic interpretation.

Quality assurance

It includes a planned system of review procedures conducted by personnel not directly involved in the laboratory process.[6] Statistical analysis of quality control provides the data for quality assurance activities where correlation of errors, complaints, failures or other unexpected results are evaluated against the laboratory expectations. Participation in external programs also contributes valuable information for a quality assurance program. Organized external quality assessment programs are available in other countries [College of American Pathologists (CAP), United Kingdom National External Quality Assessment Service (UK NEQAS)]. There are two distinct systems that can be used to deliver quality assurance such as selective system where stained preparations from departmental archival records are used to assess the quality of staining or distributive system in which participating laboratories are asked to stain sections that have been submitted by the scheme organizer.[2,5,7,8]

Continuing quality improvement

This system is used to approach, evaluate and identify opportunities to improve quality before problems occur through evaluation of all systems/processes in the laboratory. The goal is to improve potential care and safety through recognition of potential problems/errors before they can occur.[5]

Quality control and assurance plan for histopathology lab

Designing a quality control and assurance plan in histopathology should focus on three elements: (1) pre-analytical phase, (2) the analytical phase and (3) the post-analytical phase[2] as defects may occur at any of these phases, resulting in an erroneous diagnosis.

Pre-analytical aspects

It includes sample collection, transport, accession and tissue processing and submission of the slide for reporting. Studies have indicated that errors related to pre-analytical phase can endanger quality of histopathology report.[9,10] The accuracy of the final diagnosis is a measure of the effectiveness of many elements including specimen collection, gross dissection and section, tissue processing, embedding, sectioning and staining. Patient or specimen identification is one of the most important aspects and it begins with specimen labeling and accessioning.[11,12]

Other critical element is adequate clinical history and has been shown to affect the accuracy and completeness of pathology reports.[13,14] Endorse definitive laboratory specimen rejection policies to prevent further processing of and interpretation of specimens with potential demographic mismatches or pertinent clinical information. Standard operating procedure for sample accession, identification, rejection of the sample and all steps of tissue processing must be documented and displayed in laboratory and the technical staff should be aware of its contents.[2,5,12]

Precise and systematic gross description, dissection and selection of sections for microscopic study are crucial parts of the pathologic examination and often cannot be remedied if omitted or done poorly at the time of the initial work up.[15] The stages of fixation, dehydration and clearing must be of sufficient length to ensure completeness.[5,12,16]

All the equipment and instruments used in the laboratory should be of standard quality and calibrated at periodic intervals. Disposable blades can provide a sharp cutting edge from which flawless 2-4 μm sections can be cut with ease. The microscope and its parts should be serviced regularly to help in imparting an accurate diagnosis.[5,12]

In case of frozen section, it is critical that the pathologist communicates effectively with clinicians to verify clinical history, appearance and exactly what information the surgeon wants. Even though overall diagnostic accuracy of frozen section ranges from 89% to 98% in various studies, frozen artifact can produce inferior slides for microscopic examination and sampling errors can result from the heterogeneity of a tumor.[17,18,19,20] Checklists to ensure quality control during pre-analytical phase has been provided in Table 1.

Table 1

Checklists to ensure quality control during pre-analytical phase

What principles must be observed to avoid damage to the centrifuge or the specimen and danger to personnel?

Analytic aspects

The analytical phase is related to slide reading along with relevant data and preparation of report.[2] Pathologist must have judgment, be conscious of the patient's welfare and should always strive to provide accurate diagnosis. He/she must constantly seek out new knowledge and adopt new practices as they become available.

Assessment of analytical aspects in histopathology is not easy because of the subjectivity of the reports. Error detection and avoidance in histopathology has been discussed by many authors.[21,22,23] Intradepartmental discussions, comparison with other reports (frozen, cytology, or histopathology), blinded random case review, external consultations and review by experts are some of the steps which can be taken to improve the quality. Complete reporting in pathology has been given sufficient attention in recent times particularly in oncology, where many protocols are dependent on the pathological staging of tumors.[24,25,26,27]

Post-analytical aspects

Post-analytical phase involves the activities that follow the analytical phase including preparation and delivery of the report, archiving of request form and report, storage of the reported specimen for set retention period and safe disposal of specimen thereafter.[3] All slides and paraffin blocks should be stored indefinitely if facilities are available as these are of permanent nature and can be evaluated on need.[15] Laboratories should attempt to achieve the goal of signing out majority of cases in shortest time possible as turnaround time is one of the measures by which the clinician or patient will judge the laboratory.[28] The retention period for specimens has always been a subject of debate and national guidelines for this are warranted.[2,29]

Clinician satisfaction may also be dependent on expectations of a clinician from the laboratory. Therefore, in addition to managing and monitoring all the elements of quality, the pathologist must also manage clinician expectations and make sure that they are realistic.[30,31]

Safety control

All laboratories should enroll in a safety program which should begin with the recognition and understanding of the hazards, followed by implementation of safety rules and regulations. Risk management pertains not just to personal health and safety in the conventional sense, but also to environmental health and safety. Deficiencies have been reported in the knowledge, attitudes and practice of laboratory safety by laboratory personnel.[32]

Hazards associated with chemicals

A wide range of chemicals which are potentially dangerous are employed in pathology laboratories.[33] The risks associated with hazardous chemicals may be controlled by having adequate knowledge of the properties of these substances and protective equipment and preventive measures available.

Health hazard effects of chemicals

Nearly all the chemicals can be irritants, given sufficient exposure to tissue and can cause reversible inflammation specially eyes, skin and respiratory passages. The alkaline substances, strong acids, dehydrating and oxidizing agents are particularly corrosive and can damage or destroy living tissues. Chemicals that are sensitizers cause allergic reactions in a substantial proportion of exposed subjects. Sensitization may occur at work because of the high exposure level, formaldehyde being a prime example.[5,34,35] Chemicals including chloroform, chromic acid, dioxane, formaldehyde, nickel chloride and potassium dichromate and dyes such as auramine O, basic fuchsin and Congo red are carcinogenic.[5,34,36]

Toxic materials are capable of causing death by ingestion, skin contact, or inhalation at certain specified concentrations. Among the more familiar toxic substances are the cyanides and heavy metal salts which cause acute or chronic poisoning. Mercury, lead, arsenic and a number of organic substances are cumulative poisons and are injurious to health on long exposure. Methanol is toxic; chromic acid, osmium tetroxide and uranyl nitrate are highly toxic. Chemicals causing specific harm to select anatomical or physiological systems are said to have target organ effects. Their effects are not immediately evident, but are cumulative and frequently irreversible. Xylene and toluene have neurotoxic effects and benzene can affect blood.[4,5,34,36]

Physical risks of chemicals/risk from fire and explosion

Many of the commonly-used organic solvents like diethyl ether, ethyl alcohol, methyl alcohol and acetone have flash points below 21°C and are highly flammable. Some have very low ignition temperatures and can even be ignited on contact with surfaces below red heat. Explosive chemicals are rare in histology, the primary example being picric acid. Certain silver solutions may become explosive upon aging and they should never be stored after use. Oxidizers can initiate or promote combustion in other materials and may present a serious fire risk when in contact with suitable substances. Sodium iodate, mercuric oxide and chromic acid are some of the examples for oxidizers.[4,5,34,35]

Safety measures while handling hazardous chemicals

Even for substances with no known significant hazard, exposure should be minimized. Unless known otherwise, assume that any mixture will be more toxic than its most toxic component and all substances of unknown toxicity are hazardous. The permissible exposure limits (PEL) of the Occupational Safety and Health Administration (OSHA) should be observed.[4,37]

Avoid storing or handling food or beverages in storage areas, refrigerators, glassware or utensils which are used for laboratory operations.[4,37] The masks should be used when contamination is below the permissible exposure limit of hazardous materials. When contamination exceeds permissible levels, respirators should be used. The dust particle mask (yellow) should be used when weighing out powders and the charcoal mask protects against organic solvent fumes. Sleeves are disposable garments worn to protect the arms from contact with biohazards and chemicals.[33,37,38,39]

Containers of chemicals should be labeled with certain basic information: chemical name, manufacturer's name and address, storing and handling instructions, date of receipt and opening, date purchased, expiration date, hazard warnings and safety precautions.[4]

Stored chemicals should be examined periodically for replacement, deterioration and container integrity. Whenever possible, buy dangerous reagents in plastic or plastic coated glass bottles. Special storage provisions are warranted for acids, flammables, radioactive isotopes and hazardous chemicals in bulk containers. It is best to avoid flammable liquids with volatile nature and very low flash point or buy only the required quantity and do not try to store any leftovers.[5,34,37]

In the laboratory, storage on bench tops, open shelves and in hoods is inadvisable. Exposure to heat or direct sunlight should be avoided. Periodic inventories should be conducted, with unneeded items being properly disposed of or returned to the storeroom. Upon receipt and the opening of a chemical, the container must be dated.[34,37]

Identify chemicals that can be disposed of safely in normal trash or sewer systems and other chemicals must be recycled or reduced when possible, or placed in appropriate containers to be picked up by safety services. Reducing toxics use by substitution and minimization, coupled with recycling, could lead to low quantities of waste to be hauled away.[37,39] Biohazardous waste should be incinerated onsite or hauled away. Potentially infectious waste ought to be segregated from chemical or non-regulated waste.[5,37]

Risks occurring due to equipment can be minimized by proper installation, care and personnel training. Electrical shock can be minimized by properly polarizing and grounding all the outlets. Refrigerators and freezers must never be used to store highly flammable chemicals. Mechanical injuries due to hot surfaces of instruments can be avoided by adapting safety measures. Broken glass particles and disposable microtome blades should be disposed in special ‘sharp’ containers. Microtomes and cryostats must be cleaned after the removal of blades.[5] Basic principles to be followed to minimize the exposure to chemicals and also to prevent accidents related to chemicals are provided in Table 2.

Table 2

Safety measures while handling hazardous chemicals

What principles must be observed to avoid damage to the centrifuge or the specimen and danger to personnel?

HAZARDS ASSOCIATED TO PATHOGENIC MICRO-ORGANISMS

The first and most obvious source of biological risk is with fresh tissue and body fluids: grossing carries the highest risk of all histological activities. Fixed specimens have a much-reduced risk because nearly all infectious agents are readily deactivated by histological fixation.[5] The potential routes through which laboratories workers can get exposed to biohazards are inhalation of aerosols, contact with non-intact skin and contact with mucous membranes. Exposure can occur in the course of receiving, processing and disposal of these material.[4] Many have discussed on the biohazards in laboratories.[38,40,41,42]

HAZARDS ASSOCIATED WITH LABORATORY EQUIPMENT AND INSTRUMENTATION

Laboratory equipment and appliances that are electrically powered can pose an electrical problem, besides mechanical and other possible hazards. Three-to-two plug conversion adapters and extension cords are prohibited. Electrical equipment should be checked annually for grounding and current leakage. Malfunctioning equipment should be taken out of service immediately and reported to supervision.[43] The incorporation of sufficient safeguards is necessary if flammable solvents are to be used with the centrifuge. A suitable exhaust connection is required to prevent the build-up of dangerous levels of flammable gases and hazardous vapors and fumes emerging from the flame unit. The autoclave can pose hazards arising from heat, steam and pressure. The general rule for safe operation of the different instruments and even common laboratory equipment is that the operator must be guided by information in the technical manuals and by experienced persons.[4]

CONCLUSION

It is crucial to maintain and enhance quality of laboratory in line with international standards, as histopathology report influences the majority of patient treatment decisions and plays a vital role in patient safety. The journey towards quality should start with the decision to take the right sample, handled in the right manner and end with the timely implementation of the accurate treatment for the patient based on the correct interpretation of the laboratory result. Promotion of health and safety of patient, laboratory personnel and environment should be the primary objective in quality and safety control programs adopted by the histopathology laboratories.

Footnotes

Source of Support: Nil.

Conflict of Interest: None declared.

REFERENCES

1. Kohn LT, Corriga JM, Donaldson MS, editors. Washington (DC): National Academy Press; 1999. To Err is Human: Building a Safer Health System. [Google Scholar]

2. Iyengar JN. Quality control in the histopathology laboratory: an overview with stress on the need for a structured national external quality assessment scheme. Indian J Pathol Microbiol. 2009;52:1–5. [PubMed] [Google Scholar]

3. Berte LM. Laboratory quality management: a roadmap. Clin Lab Med. 2007;27:771–90. [PubMed] [Google Scholar]

4. Jegathesan M, Chin CS, Lim HH. Safety in pathology laboratories. Malays J Pathol. 1988;10:1–5. [PubMed] [Google Scholar]

5. Bancroft JD, Gamble M. 6th ed. London: Churchill Livingstone; 2008. Theory and Practice of Histological Techniques. [Google Scholar]

6. Joe Mangino. Chaper 8: Quality Assurance and Quality Control. In: Simon Eggelston, Leandro Buendia, Kyoko Miwa, Todd Ngara, Kiyoto Tanabe., editors. IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories. 1st ed. Geneva (Switzerland): The Institute for Global Environmental Strategies (IGES) for the IPCC; 2006. [Last accessed on 2011 Jun 06]. Available from: http://www.ipcc-nggip.iges.or.jp/public/gp/english/8_QA-QC.pdf . [Google Scholar]

8. Sergi C, Mikuz G. External quality assurance as a revalidation method for pathologists in pediatric histopathology: comparison of four international programs. BMC Clin Pathol. 2008;8:11. [PMC free article] [PubMed] [Google Scholar]

9. Wiwantikit V. Types and frequency of pre-analytical mistakes in the first Thai ISO 9002: 1994 certified clinical laboratory, a 6 month monitoring. BMC Clin Pathol. 2001;1:5. [PMC free article] [PubMed] [Google Scholar]

10. Sharif MQ, Mushtaq S, Mamoon N, Jamal S, Luqman M. Clinician's responsibility in pre-analytical quality assurance of histopathology. Pak J Med Sci. 2007;23:720–3. [Google Scholar]

11. Nakhleh RE. Lost, mislabeled and unsuitable surgical pathology specimens. Pathol Case Rev. 2003;8:98–102. [Google Scholar]

12. Culling CF, Allison RT, Barr WT. 4th ed. London: Butterworth pub; 1985. Cellular Pathology Technique. [Google Scholar]

13. Nakhleh RE, Zarbo RJ. Surgical pathology specimen identification and accessioning: A College of American Pathologists Q-Probes study of 1,004,115 cases from 417 institutions. Arch Pathol Lab Med. 1996;120:227–33. [PubMed] [Google Scholar]

14. Nakhleh RE, Gephardt G, Zarbo RJ. Necessity of clinical information in surgical pathology: A College of American Pathologists Q-probes study of 771,475 surgical pathology cases from 341 institutions. Arch Pathol Lab Med. 1999;123:615–9. [PubMed] [Google Scholar]

15. Rosai J. 8th ed. Vol. 1. St. Louis: Mosby-Year Book Inc; 1996. Ackerman's Surgical Pathology. [Google Scholar]

16. Bancroft JD, Cook HC. Edinburgh: Churchill Livingstone; 1994. Manual of Histological Techniques and their Diagnostic Application. [Google Scholar]

17. Bui MM, Smith P, Agresta SV, Cheong D, Letson GD. Practical issues of intraoperative frozen section diagnosis of bone and soft tissue lesions. Cancer Control. 2008;15:7–12. [PubMed] [Google Scholar]

18. Howanitz PJ, Hoffman GG, Zarbo RJ. The accuracy of frozen-section diagnoses in 34 hospitals. Arch Pathol Lab Med. 1990;114:355–9. [PubMed] [Google Scholar]

19. Dalal BL, Malik AK, Datta BN. Frozen section diagnosis- a review of 1051 cases. Indian J Cancer. 1979;16:59–65. [PubMed] [Google Scholar]

20. Holaday WJ, Assor D. Ten thousand consecutive frozen sections: a retrospective study focusing on accuracy and quality control. Am J Clin Pathol. 1974;61:769–77. [PubMed] [Google Scholar]

21. Ramsay AD. Errors in histopathology reporting: Detection and avoidance. Histopathology. 1999;34:481–90. [PubMed] [Google Scholar]

22. Zuk JA, Kenyon WE, Myskow MW. Audit in histopathology: description of an internal quality assessment scheme with analysis of preliminary results. J Clin Pathol. 1991;44:10–6. [PMC free article] [PubMed] [Google Scholar]

24. Marchevsky AM, Wick MR. Evidence-based medicine, medical decision analysis, and pathology. Hum Pathol. 2004;35:1179–88. [PubMed] [Google Scholar]

25. Commission on Cancer. Standard 4.6. The guidelines for patient management and treatment currently required by the CoC are followed. Commission on Cancer of the College of American Surgeons Cancer Program Standards. [Last accessed on 2011 May 26]. Available from: http://www.facs.org/cancer/coc/standardsclarifications.html .

28. Zarbo RJ, Gephardt GN, Howanitz PJ. Intralaboratory timeliness of surgical pathology reports: results of two College of American Pathologists Q-probes studies of biopsy and complex specimens. Arch Pathol Lab Med. 1996;120:234–44. [PubMed] [Google Scholar]

29. Hollensead SC, Lockwood WB, Elin RJ. Errors in pathology and laboratory medicine: consequences and prevention. J Surg Oncol. 2004;88:161–81. [PubMed] [Google Scholar]

30. Zarbo RJ, Nakhleh RE, Walsh M Quality Practices Committee, College of American Pathologists. Customer satisfaction in anatomic pathology. A College of American Pathologist Q-probes study of 3065 physician surveys from 94 laboratories. Arch Pathol Lab Med. 2003;127:23–9. [PubMed] [Google Scholar]

31. Nakhleh RE, Jones B, Zarbo RJ. Mammographically directed breast biopsies: A Q-probes study of clinical physician expectations, specimen handling and reporting characteristics in 434 institutions. Arch Pathol Lab Med. 1997;121:11–8. [PubMed] [Google Scholar]

32. Ejilemele AA, Ojule AC. Knowledge, attitude and practice of aspects of laboratory safety in Pathology Laboratories at the University of Port Harcourt Teaching Hospital, Nigeria. Niger J Clin Pract. 2005;8:102–6. [PubMed] [Google Scholar]

33. Steere NV, editor. 2nd ed. Boca Raton: CRC Press Inc; 1971. Handbook of Laboratory Safety. [Google Scholar]

34. 2nd ed. Wayne, Pennsylvania 19087-1898 USA: NCCLS. Clinical Laboratory Safety; Approved Guideline— Document GP17-A2 (ISBN 1-56238-530-5); 2004. [Last accessed on 21-06-2-11]. Available from: www.clsi.org/source/orders/free/gp17-a2.pdf . [Google Scholar]

35. National Institute for Occupational Safety and Health. NIOSH pocket guide to chemical hazards. DHHS (NIOSH) Publication No. 2005-149; 2005. [Last accessed on 2011 Jul 01]. Available from: www.cdc.gov/niosh/docs/2005-149/pdfs/2005-149.pdf . [Google Scholar]

36. Dapson JC, Dapson RW. 4th ed. Battle Creek: Anatech Ltd; 2005. Hazardous materials in the histopathology laboratory: regulations, risks, handling and disposal. [Google Scholar]

37. Washington: National Academy Press; 1988. [Last accessed on 2011 Jul 01]. National Research Council. Prudent Practices for Handling Hazardous Chemicals in Laboratories; pp. 233–5. Available from: library.med.utah.edu/WebPath/Histhtml/./Workchem.Pdf . [Google Scholar]

38. Miller BM. Washington: American Society for Microbiology; 1986. Laboratory Safety: Principles and Practices. [Google Scholar]

39. Stricoff RS, Walters DB. New York: Wiley; 1990. Laboratory health and safety handbook: A guide for the preparation of a chemical hygiene plan. [Google Scholar]

40. Pike RM. Past and present hazards of working with infectious agents. Arch Pathol Lab Med. 1978;102:333–6. [PubMed] [Google Scholar]

41. Pike RM. Laboratory-associated infections: Summary and analysis of 3921 cases. Health Lab Sci. 1976;13:105–14. [PubMed] [Google Scholar]

42. Collins CH. London: Butterworths and Co. Ltd; 1983. Laboratory-Acquired Infections. [Google Scholar]


Articles from Journal of Oral and Maxillofacial Pathology : JOMFP are provided here courtesy of Wolters Kluwer -- Medknow Publications


What precautions should be observed in centrifugation?

Safe Operation.
Use safety cups whenever possible..
Disinfect or clean weekly and after all spills or breakages..
Lubricate O-rings and rotor threads weekly..
Do not operate the centrifuge without the rotor properly balanced..
Do not use rotors that have been dropped..

What are the principles behind the use of a centrifuge?

A centrifuge works by using the principle of sedimentation: Under the influence of gravitational force (g-force), substances separate according to their density. Different types of separation are known, including isopycnic, ultrafiltration, density gradient, phase separation, and pelleting.

What is one of the most important rules when using a centrifuge?

Do not bump, jar, or move the centrifuge while the rotor is spinning. Instruct all other persons in the area to stay clear of the unit while it's operating. Make sure you don't have the cord dangling from a table edge where someone could catch their foot in it and pull down the centrifuge.

What are the steps you can take to avoid imbalance in centrifuge?

Ensure that your work surface is level and firm. Do not use the centrifuge on an uneven or slanted work surface. At high speeds, a centrifuge can easily become unbalanced if equal masses are not located opposite each other in the rotor: For fixed-angle rotors, balance your tubes according to their weight.